Pool Heat Pump, How Much Do You Know about It?

Author:gtheatpump 2023-04-20 17:01:51 73 0 0

Hotel pool heat pump

A hotel pool heat pump is a heating device that focuses on hot water for hotel pools, using the inverse Carnot principle to absorb heat from the surrounding air and transfer it to the pool water. Indoor hotel pools, using pool constant temperature dehumidification heat pump, running in dehumidification + heating mode, is the use of dehumidification (cooling) to recover the energy in the air for heating pool water, in order to achieve the effect of energy saving.

 

Hotel pool heat pump - market status and trends

With the improvement of people's living standards, hotels are no longer just a place for tourists to stay for a short period of time, but today's hotels also provide restaurants, swimming pools, fitness and other services for tourists in addition to providing accommodation. Bowling/golf courses, fitness and spa and beauty center, each of them are the best in today's hotels, which at the same time set off the pool heat pump in the hotel field.

 

Hotel pool heat pump - working principle

Hotel pool heat pump is the use of the principle of inverse Carnot cycle of the hotel indoor pool water evaporation away the heat recovery and release into the pool water or indoor air, so as to make the pool constant temperature and indoor temperature, and to achieve the dehumidification effect of a device.

That is, a small amount of electrical energy to drive the compressor operation, high pressure liquid mass after the expansion valve in the evaporator evaporates into a gaseous state, and a large amount of heat energy in the ambient air, gaseous mass is compressed by the compressor into a high-temperature, high-pressure liquid, and then into the condenser exothermic water heating, so constantly cycle heating pool water.

In the hotel pool constant temperature dehumidification, air conditioning system design, we use heat pump energy recovery system, fully absorb the heat energy in the hotel indoor hot humid air for pool water heating. This not only saves a lot of energy, but also makes the hotel indoor air achieve the purpose of dehumidification.

 

Hotel pool heat pump - system features

Adopting full heat recovery technology, when dehumidifying (cooling) operation, all the heat originally discharged to the environment will be recovered through full heat recovery technology and used to heat the pool water to achieve the purpose of energy saving and consumption reduction.

Stable and reliable: The new system design overcomes the shortcomings of traditional heat recovery system with long circuit and difficult oil return, and with the compressor of international famous brand and patented technology of high efficiency casing, the cooling and heating are more powerful.

Energy-saving and environmental protection: using heat pump technology, compared with other conventional hot water equipment (such as: oil boilers, gas boilers, electric boilers, etc.) can save 65% ~ 80% of the operating costs, no pollution to the environment.

Safety in use: water and electricity isolation; no open flame, no leakage, to ensure personal safety.

Intelligent control: it can realize independent temperature control, intelligent frost and fully automatic switching of various modes.

 

Hotel pool heat pump - energy-saving solutions

Outdoor swimming pool constant temperature solution

Adopting air source pool heat pump, the refrigerant evaporates by absorbing the heat energy in the ambient air, and the gaseous mass is compressed by the compressor into high temperature and high pressure liquid state, then it enters the condenser to exotherm to heat the water, and so on to heat the pool water continuously.

 

Pool Heat Pump, How Much Do You Know about It?

 

Indoor swimming pool constant temperature and humidity solution

Due to the evaporation of indoor pool water, indoor humidity increases, in order to ensure indoor comfort, the need to reduce the indoor moisture content, dehumidification is a cooling process, the use of pool constant temperature dehumidification heat pump can recover the heat in the dehumidification process, the transfer to the indoor air and pool water. To ensure the temperature of indoor air and pool water temperature.

 

Hotel pool maintenance measures

Folded primary filter is checked every half month, blowing with compressed air or water washing, water washing can be cleaned 2~3 times (to fabric not broken shall prevail), usually half a year to replace; differential pressure resistance replacement range is 100~180 Pa. Every half month to check whether the electric heater is damaged, whether the connecting wire is burnt, if necessary, the connecting wire should be replaced.

After one month of normal operation, the unit should be stopped to check the tightness of the belt and adjusted; with oiling holes should be filled with lubricant; check whether the bolts of key parts are loose and tighten them.

If the unit runs all year round, the grease of the bearings of the fan and motor should be added once every six months; those who stop in the transitional season should also be guaranteed to be added once a year.

After two years of operation, the unit should be fully maintained. Chemically remove the scale inside the heat exchanger tube, and then flush the fin surface with compressed air or water.

 

Hotel pool installation precautions

1. Read the random product manual carefully before installation.

2. The unit must be installed in a location with good ventilation conditions.

3. The installation location should be convenient for debugging and maintenance, leaving a maintenance gap.

4. The installation position should be far from the place where strong electricity and strong magnetic field act directly.

5. The unit must be installed with vibration damping devices to prevent vibration from being transmitted to the building.

6. The host supply and return pipes are flexibly connected, which can prevent vibration from the unit from spreading to the water pipes.

7. Water pipes must be well insulated to prevent energy loss

8. The outdoor pipeline must be well wrapped with aluminum or galvanized iron after insulation.