During summer, especially in hot and humid environments, laser condensation (dew formation) can easily occur. This is particularly dangerous for precision equipment like fiber lasers, potentially leading to optical contamination, fiber damage, or even permanent laser failure. The following measures can effectively help prevent condensation on lasers:

Condensation happens when the surface temperature of the device falls below the dew point of the ambient air, causing moisture to form as water droplets on cold surfaces.
In summer, air conditioning lowers indoor temperatures while outdoor humidity remains high.
This causes laser surfaces or internal components to drop below the dew point, resulting in condensation.
Optical interfaces and light paths are the most vulnerable areas.
Maintain relative humidity ≤ 60%
Use industrial dehumidifiers, especially in humid regions or during rainy seasons
Set air conditioning to “dehumidify” mode, which is more effective than standard cooling
Avoid very low indoor temperatures—keep it around 24°C to 28°C (75°F to 82°F)
Limit indoor-outdoor temperature differences to within 8°C (14°F) to reduce condensation risk
Do not power on the laser immediately after a rapid temperature change
Let the machine run in standby or cooling mode for 10–30 minutes to stabilize temperatures
Check fiber connectors, lenses, and optical modules for proper sealing
Prevent external moisture from entering the laser path
High-end systems may allow dry air or nitrogen purging into the optical cavity to prevent condensation
Optional: Install temperature, humidity, or dew point sensors to provide early warnings of condensation risk
| Timing | Recommended Action |
| Before powering on | Check room temperature and humidity; ensure dew point is below laser surface temp |
| When using A/C | Enable dehumidification mode or run a dehumidifier simultaneously |
| After long shutdown | Run cooling/standby mode for 10–30 minutes before powering on the laser |
| When not in use | Keep the device in a well-ventilated or dry environment; use constant temp/humidity if needed |
To prevent laser condensation in summer, the key is:
Humidity control > Temperature control
Maintain temperature above dew point
Good sealing + Standard operating practices
If you are using a specific fiber laser brand (e.g., IPG, Raycus, MAX, etc.), I can also provide brand-specific condensation prevention guidelines. Just let me know the model or brand.Welcome to contact us!
Learn more:
Fiber laser cutting machines;CO2 Laser Machine; Tube Fiber Laser Cutting Machine;Plasma Cutting Machine
Copyright:@2020-2021